absolute filter, 197

ac motors, 28

ac voltage, checking, 19

accumulator, 119

heat pump, 246

accurater, 156

accustats, 115-116

air conditioning operation, 163-165

three sections of, 30

air filtration, 190-201

filter changing frequency for, 196

filter efficiency in, 197

filters for, 196

magnamedia or absolute filters, 197

manometer in, 199

scrubbers in, 198

air handler (see evaporator) air ways, 164

air-cooled condenser, 141

alien wrenches, 315

aluminum wiring, 6

ampacity of, 10

ambient control (compressor), 97

ambient thermostats, 116

ammeter, 20, 26, 27, 309

checking current with, 24

circuitry of, 25

dc, checking current with, 25

ampacity

aluminum wire, 10

copper wire, 9

amperage, testing for, 23

armatures, 57, 58

automatic expansion valve, 155

automotive air conditioning, 278-286

clutch assembly for, 280

recharging system for, 285

refrigerant for, 285

axial fans, 202

rotation rules for, 206

B

basic electricity, 1-18

bellows thermostat, 109

belts (see pulleys and belts), 213

bimetal contacts, 61, 82

bimetal thermostats, 109

bonnet and pigtail, 188

branch circuit, 2

breaker for, 4

increasing load in, 6

modifications to, 5

bus bars, 79

C

Calrods, 295

capacitor start motors, 48

capacitors, 13, 29, 48

discharging of, 51

hold-a-charge test for, 52

indexing of, 51

permanent split (PSC), 53

run, 49

start, 49

testing of, 51

types of, 49

capillary tube metering device, 155,156

Celsius to Fahrenheit conversion, 136

centrifugal fans, 202

charging chart, 229, 230

charging systems, 228-237

air conditioning tables for, 228

crimping in, 235

cylinders, 232

king valve for, 237

line tap valve for, 236

Schraeder valve for, 236

service manifold and gauges in, 230

service valves in, 233

sight glasses in, 231

circuit breakers, 2, 4, 8, 22, 71-81, 89

arcing in, 78

bus bars in, 79

continuity testing of, 76

fuses vs., 55

internal view of panel of, 78

lever-type disconnect for, 73

linked, 81

non-trip, 71, 74

panel showing, 77

premature tripping in, 75

pull-type disconnect for, 72

quick-trip, 74

testing of, 75

time-delay (slow trip), 75

tripped, 270

circuit elements, 28

circuitry, 14

circulating pump (solar), 327

clutch assembly, automotive air conditioning, 280

coil-in-shell water-cooled condenser, 148

coils, 12, 29, 58

cold water pipe ground, 3

collector (solar), 327, 328

components, evaluation of electrical, 28

compression fittings, 183

compressor reed valves, 47

compressors, 30-47

ambient control for, 97

automotive, 279

capacitor start motor diagram for, 43

cleaning up burn-out in, 271-274

continuity testing of, 40

electrical connecting terminals for, 39

electrical failure testing of, 40

hermetic, 32

horsepower requirements for capacitors on, 53

hot-shotting, 45

internal-mounted, noise from, 274

locked rotor test, 42

open-drive, 37

preventive maintenance for, 262-263

rebuilding vs. replacing, 36

reciprocal, 138, 140

refrigeration valves for, 47

refrigerator, 303

reverse rotation technique for, 46

“ringing out”, 42

rotation in, 41

semi-hermetic, 37

testing for grounded, 41

testing for open-windings, 41

testing of, 39

computerized controls, 323

condenser/condensing unit, 30

accumulator for, 119

air-cooled, 141

automotive, 282

capacitor mounting on, 52

coil cross section for, 142

compressor in, 32

crankcase heater for, 118

domestic refrigerator, 303

driers-dehydrators, 120

hot gas muffler for, 120

inoperative, 267

insufficient cooling from operational, 269

leak testing for, 221

optional components in, 118-125

placement of, 163

preventive maintenance for, 261-262

purpose of, 30

receiver for, 119

replaceable-core, shell-type filter/drier, 123

servicing, 31

sight glasses for, 124

solenoid valves for, 124

strainers for, 123

walk-in freezers, 297

water-cooled, 144

conductor fill, 7

chart for EMT, 11

conductors, 6, 16

aluminum, ampacity of, 10

coppper, ampacity of, 9

conduit, 3, 16

diameter and carrying capacity of, 7

contactor, 57

motor starter action of, 82

relays vs., 61-63

contacts, bimetallic, 61

continuity testing

circuit breakers, 76

compressor, 40

transformers, 69

control wires, distance to tranformer from, 66

coolants (see refrigerants), 131

copper piping, 173

copper wire, 6

ampacity of, 9

crankcase heaters, 118

crimping tool, 321

current, 7, 13

checking for, 24, 25

equation for, 16

voltage vs., 7

current relay, 57

cylinders, charging, 232

D

dampers, 142, 143

dc ammeter (see ammeter)

de-ice or defrost control, 98

defrost heater circuit, 296

defrost timer, 305-308

dehumidification, 159

dehydrators, 120

sizing for, 122

delta-wired load, 12

dewpoint temperature, 158

dichlorodifluoromethane, 132, 133

differential (thermostats), 111

direct expansion evaporator, 143

distribution panel, schematic of three-phase, 12

driers (condensing unit), 120

drills, 312

dry desiccant filter-drier, 191

dry-bulb temperature, 158

dual-voltage six windings, 86

DX evaporator, 143

E

electrical components, evaluation of, 28

electrical safety controls, 90

electrical symbols, 128

electricity, 1-18

electronic filters, 197

electronic thermostat, 109

electrostatic precipitator, 197

EMT conduit, 16

entrance panels, 2, 8, 22

service head and, 3

evaporator, 30, 99-105

heat strips in, 99

inoperative, 267

insufficient cooling from operational, 269

leak testing for, 223

mechanical refrigeration system, 153

multiple, 301

noisy, 276

placement of, 164

preventive maintenance for, 263-265, 263

refrigerator, 306

warm air from, 267

F

fan systems, 202-212

air-foil shaped blades in, 203

cycling control for, 97

direction of discharge air and rotation in, 210

drive arrangements for, 211

increasing CFM by increasing motor speed in, 208

motor mounting positions for, 211

mounting techniques for, 211

noisy, 276

propeller fan rotation rules, 206

pulley and belt size for, 217

throttling of, 209

throttling water pumps in, 209

vibration control in, 210

feeder wire, 5

fifty-fifty solder, 177

filter drier, 190-201

automotive, 281

dry desiccant, 191

hand valve installation for, 194

in-line, 190

installation of, 193

liquid line, 190

replaceable-core shell-type, 123

shell-and-core, 193

strainer in, 195

suction line, 191

filters

air, 196

electronic, 197

electrostatic precipitator, 197

magnamedia or absolute, 197

fire stat, 166, 167

flare and compression fittings, 182-189

copper bonnet and pigtail for, 188

proper technique for, 186

flare nut wrenches, 184, 186

flaring tool, 318

Freon (see refrigerants), 131

fuse links, 102

fuse-stat, 54

fuses, 2, 28, 48, 54, 55, 89

automotive, 67

blown, 270

heat strip, 100

protecting transformers with, 68

testing of, 56

G

galvanized piping, 175

geothermodynamics, 323-325

graphical charging chart, 229

grounded compressor test, 41

grounds, 3

H

head pressure (water-cooled condensers), 152

heat pumps, 240-251

accumulator for, 246

basic operation of, 241

compressor for, 242

defrost thermostat for, 247

receiver for, 249, 250

refrigerant flow, cooling mode, 251

refrigerant flow, heat mode, 250

reversing valve in, 244

solenoid valve for, 243

valve positioning for, 245

heat reclaim, 287-289, 326

heat strips, 99

fuses in, 100

limit switch in, 99

sail switches in, 100

sequencers in, 101

water float switch in, 105

hermetic compressor, 32

components of, 35

electrical connecting terminals for, 39

high and low side of, 35

rotation in, 41

window unit, 255

high pressure controls, 93-95

hold-a-charge test (capacitors), 52

hot air solar collectors, 328

hot gas (discharge line) pulsations, 275

hot gas mufflers (condensing unit), 120, 121

hot water sensing thermostat (solar), 327

hot-shotting compressors, 45

hot-wire relay, 59, 60

humidistat, 161

humidity control, 158-162

I

icing on suction lines, 269

in-line filter-driers, 190

induced-draft/forced-draft water tower, 151

insufficient cooling, 269, 270

icing on suction lines, 269

intermittant operation, 271

internal-mounted compressors, noise from, 274

isolation test, 223

J

jumper wire, 2

K

king valve, 237

Klixon overload relay, 90

L

leak detector, 312

leak testing, 221-227

isolation test, 223

vacuum pump in, 225

limit switch, 99

insertion type, 102

surface mount, 101

line side, 2

line tap valve, 236

linked circuit breaker, 81

liquid line filter-drier, 190

load side, 2

lock-out relay, 130

locked rotor, 42, 46, 88

amperages for, 45

hot-shotting, 45

reverse rotation technique for, 46

low pressure control, 96

low-voltage wiring circuit, 129

M

magnamedia filter, 197

manifold and gauges, 310

manometer, 199-201

mechanical protection controls, 93

mechanical refrigeration system, 138-157

compressor for, 140

condenser for, 141

dampers in, 142

evaporator-DX, 153

fan cycling in, 142

metering devices for, 154

water source for, 149

water-cooled condenser for, 144

metering devices, 154

accurater, 156

automatic expansion valve, 155

capillary tube, 155

thermostatic expansion valve, 154

meters (electricity), 2, 4, 7, 8

calculating rate charges from, 9, 10

mechanical refrigeration system, 154

schematic of, 12

monochlorodifluoromethane, 132

motor starters, 82-88

auxiliary switches for, 84

bimetal contact switch in, 82

contactors vs., 82

manual, 84

rotation direction and, 88

motors

capacitor start, 48

capacitor start and run, 48

capacitor types used in, 49

noisy bearings in, 275

repulsion induction, 49

schematic of, 85

shaded-pole, 48

single-phase, operating currents for, 44

split-phase, 48

three-phase, operating currents for, 44

multimeter, 20, 309

circuitry of, 21

ohmmeter use of, 24

testing compressor with, 40

N

network (electric), 1

ninety-five-five solder, 177

noise control, 163, 274

evaporator, 276

fan systems, 208, 276

hot gas pulsations, 275

motor bearings, 275

reversing valves, 276

vibration and, 275

non-trip circuit breakers, 71

nut drivers, 314

O

odors, 277

Ohm’s law, 13, 28

ohmmeter, 21

basic circuitry for, 23

multimeter used as, 24

oil pressure failure control, 168, 171

oil trap, 175

once-through water sources, 149

open-drive compressor, 37

open-windings, 41

optional controls, 166-172

ORO valve, 298

gas routing through, 299

overload relay, 89, 91, 92

oxygen-acetylene soldering outfit, 312

P

parallel circuits, 14, 15

permanent split capacitor (PSC), 53

pigtail, 188

pipe cutter, 185

piping, 173-175

bonnets and pigtails for, 188

brass fittings for, 183

cutting of, 182, 185

flare and compression fittings for, 182-189

oil trap in, 175

soft copper seats for, 187

tools for, 184

vibration eliminator in, 180

pneumatic thermostatic controls, 113-115

pneumatic valve, 116

polyphase motors (see three-phase motors), 53

potential relay, 58, 60

pressure control valve

automotive, 284

water, 152

pressure relief devices, 95

pressure switch, 167, 169

preventive maintenance, 261-265

propeller fans (see axial fans) psychrometer, 159

psychrometrics, 158

pulleys and belts, 213-220

belt replacement in, 216

double-sheaved pulley in, 219

fan speeds and, 217

fixed single pulley in, 215

measuring for size of, 214

sheave alignment in, 218, 219, 220

single-sheaved pulley in, 216

width chart for, 215

PVC conduit, 16

PVC piping, 174

Q

quick-blow element, 55

quick-trip circuit breakers, 74

R

R-11 refrigerant, 133

R-12 refrigerant, 132

automotive air conditioning system and, 285

mechanical refrigeration system and, 138

R-22 refrigerant, 132

mechanical refrigeration system and, 138

R-500 refrigerant, 133

re-heat process, 159

reach-in coolers, 299

multiple evaporators in, 301

receiver, 119

automotive, 281

heat pump, 249, 250

reciprocal mechanical system, 138,139

components of, 139

compressor for, 140

condenser, 141

evaporator-DX, 153

metering devices for, 154

water source for, 149

reed valves, 47

refrigerants

color coding of, 133

operating pressures for, 144

properties of, 131-137

R-11 trichloromonofluoromethane, 133

R-12 (dichlorodifluoromethane), 132

R-22 (monochlorodifluoromethane), 132

R-500 (dichlorodifluoromethane), 133

safety in handling, 135

temperature/pressure chart for, 134

refrigeration, 290-308

condensing section for, 293

defrost heater circuit and switches for, 296

domestic refrigerator, 301

door seals for, 300

multiple evaporators in, 301

reach-in coolers, 299

remote systems for, 290

walk-in coolers, 291

walk-in freezers, 295

refrigeration valves, 47

refrigerators, 301-308

compressor for, 303

condensing section for, 303

defrost timer for, 305, 308

evaporator fan and motor in, 306

power supply to, 302

refrigerant pressure in, 305

relative humidity, 158

relays, 57

bimetallic contacts in, 61

contactors vs., 61-63

current, 57

hot-wire, 59

Klixon overload, 90

lock-out, 130

overload, 89, 91, 92

potential, 58

single-pole, single-throw, 59

time-delay, 91, 93

remote refrigeration systems, 290

replaceable-core shell-type filter/drier, 123

repulsion induction motors, 49

resistance, 13

checking, 21

circuits, 12, 14

electrical components, 28

resistive rods, 295

resistors, 28

reverse rotation technique (compressors), 46

reversing valve (heat pumps), 244

noisy, 276

Romex, 3, 16

rotation (compressor) test, 41

run capacitors, 49

compressor horsepower and, 53

S

safety controls, 89-98

sail switch, 100, 103, 167, 169

Schraeder valves, 223, 236

scrubbers, 198

seats, 187

semi-hermetic compressors, 37

electrical connecting terminals for, 39

field repairs for, 238-239

sequencers, 101, 103

series circuits, 14, 15

service disconnect codes, 71

service entrance conduit, 3

service head, 3, 6

service manifold, 230

service valves, 189, 234, 319

charging and, 233

shaded-pole motors, 48

sheave alignment, 218, 219, 220

shell-and-core filter-drier, 193

sight glasses, 124

charging systems and, 231

Sil-Fos solder, 177

silver solder, 178

single-phase motor, 86, 87

operating currents for, 44

single-pole, single-throw relay, 59

sling psychrometer, 159, 160

slow trip circuit breakers, 75

slow-blow element, 55

smoke detector, 166, 168

solar energy, 326-329

soldering, 176-181

tools for, 312, 313

solenoid valves (condensing unit), 124, 171

split-phase motors, 48

squirrel cage fans (see centrifugal fans), 202

star-wired load, 12

start capacitors, 49, 53

compressor horsepower and, 53

Stay Brite solder, 177

step-down transformers, 1-3, 5, 65

step-up transformers, 68

strainers (condensing unit), 123, 195

substations, 4

suction line filter-driers, 191

supplemental heat control, 97

swaging tool, 318

switches, 28, 57

T

temperature control valve, 292

temperature conversion chart: Celsius to Fahrenheit, 136

temperature/pressure chart, 134

ten-percent electrical variance rule, 69

test meters, 19-29

TEX valve, 292

thermistors, 28

thermo-bank, 327

thermometers, 315

thermostatic expansion valve, 154

automotive, 283

thermostats, 30, 106-117

accustats as, 115

ambient, 116

bi-metal, 109

differential in, 111

hot water (solar) sensing, 327

leveling sub-base for mercury switch, 111

pneumatics in, 113

preventive maintenance for, 265

sub-base for, 107, 108, 110

wiring requirements for, 110

three-phase distribution panel and meter, 12

three-phase motors, 53

operating currents for, 44

wiring details of, 84

throttling fans, 209

time-delay circuit breaker, 75

time-delay relays, 91, 93

tools, 309-322

transformer, 64-70

distance between control and, 66

installing protection fuse for, 68

placement of, 164

primary and secondary windings of, 64

step-down, 65

step-up, 68

testing of, 69

wattage rating for, 65

trichloromonofluoromethane, 133

troubleshooting, 266-277

blown fuse or tripped circuit breaker, 270

cleaning up compressor burn-out, 271-274

condensing unit and evaporator inoperative, 267

evaporator blowing warm air, 267

insufficient cooling, 269, 270

insufficient cooling, icing on suction lines, 269

intermittant operation, 271

noise, 274

odors, 277

tube-and-tube water-cooled condenser, 146

tube-in-shell water-cooled condenser, 148

tubing cutter, 185, 318

V

vacuum pump, 225

vibration control, 275

fan systems, 208, 210

vibration eliminator, 180, 181

volt-amps, 65

voltage, 13

ac, checking, 19

current vs., 7

testing for, 23

voltmeter, circuit breaker testing with, 75

W

walk-in coolers, 291

walk-in freezers

condensing section for, 297

refrigerants used for, 295

water float switch, 105

water pumps, throttling of, 209

water sources

induced-draft/forced-draft tower, 151

once-through, 149

water tower, 149

water towers, 149

induced-draft/forced-draft, 151

water-cooled condensers, 144, 145

acid circulating pump, 147

coil-in-shell, 148

head pressure in, 152

tube-and-tube, 146

tube-in-shell, 148

watts, equation for, 65

wet-bulb temperature, 158

windings, 29, 64

window units, 252-260

wire

coding abbreviations for, 18

cords chart for, 17

current in, 7

diameter and carrying capacity of, 6

wiring schematics, 126-130

abbreviations used in, 130

electrical symbols used in, 128