References and suggested readings
- Achten E, Boon P, Van De Kerckhove T, Caemaert J, De Reuek J, Kunnen M (1997) Value of single-voxel proton MR spectroscopy in temporal lobe epilepsy. AJNR: American Journal of Neuroradiology 18: 1131–1139.
- ACR (2013) ACR Manual on Contrast Media: Version 9.
- Bernstein MA, King KF, Zhou XJ (2004) Handbook of MRI Pulse Sequences. Elsevier Academic Press, Burlington, MA.
- Block T, Frahm J (2005) Spiral imaging: a critical appraisal. Journal of Magnetic Resonance Imaging 21: 657–668.
- CKD Work Group (2013) Kidney Disease: Improving Global Outcomes (KDIGO). KDIGO 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. Kidney International 3 (Suppl.): 1–150.
- Debatin JF, McKinnon GC (eds.) (1998) Ultrafast MRI: Techniques and Applications. Springer-Verlag, Heidelberg.
- De Graaf RA (2007) In vivo NMR Spectroscopy: Principles and Techniques, Second edition. John Wiley & Sons, Ltd, Chichester, West Sussex, England.
- DeYoe EA, Bandettini P, Neitz J, Miller D, Winans P (1994) Functional magnetic resonance imaging (FMRI) of the human brain. Journal of Neuroscience Methods 54: 171–187.
- DIN (2008) Magnetic Resonance Equipment for Human Application – Classification Criteria for Pulse Sequences, PAS 1081. Deutsches Institut für Normung e.V.
- Dixon WT (1984) Simple proton spectroscopic imaging. Radiology 153: 189–194.
- Edelman RR, Wielopolski P, Schmitt F (1994) Echo-planar MR imaging. Radiology 192: 600–612.
- Finelli DA, Kaufman B (1993) Varied microcirculation of pituitary adenomas at rapid, dynamic contrast-enhanced MR imaging. Radiology 189: 205–210.
- Govindaraju V, Young K, Maudsley AA (2000) Proton NMR chemical shifts and coupling constants for brain metabolites. NMR in Biomedicine 13: 129–153.
- Guyton AC, Hall JE (1996) Textbook of Medical Physiology, 9th edition. W. B. Saunders, Philadelphia, PA.
- Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) Magnetic Resonance Imaging: Physical Principles and Sequence Design. Wiley-Liss, New York.
- Hendrick RE (ed.) (2005) Glossary of MR Terms, 5th edition. American College of Radiology, Reston, Virginia.
- Henkelman RM, Bronskill MJ (1987) Artifacts in magnetic resonance imaging. Reviews of Magnetic Resonance in Medicine 2: 1–126.
- Hetherington HP, Pan JW, Chu W-J, Mason GF, Newcomer BR (1997) Biological and clinical MRS at ultra-high field. NMR in Biomedicine 10: 360–371.
- Kanal E, Barkovich AJ, Bell C, et al. (2007) ACR Guidance Document for Safe MR Practices: 2007. American Journal of Roentgenology 188: 1447–1474.
- Kingsley PB (2006) Introduction to diffusion tensor imaging mathematics: Part I. Tensors, rotations, and eigenvectors. Concepts in Magnetic Resonance 28A: 101–122;Part II. Anisotropy, diffusion weighting factors, and gradient encoding schemes. Concepts in Magnetic Resonance 28A: 123–154;Part III. Tensor calculation, noise, simulations, and optimizations. Concepts in Magnetic Resonance 28A, 155–179.
- Kuo PH, Kanal E, Abu-Alfa AK, Cowper SE (2007) Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology 242: 647–649.
- Kvistad KA, Rydland J, Vainio J, Smethurst HB, Lundgren S, Fjøsne HE, Haraldseth O (2000) Breast lesions: evaluation with dynamic contrast-enhanced T1-weighted MR imaging and with T2*-weighted first-pass perfusion MR imaging. Radiology August, 216(2): 545–553.
- Le Bihan D (ed.) (1995) Diffusion and Perfusion Magnetic Resonance Imaging: Applications to Functional MRI. Raven Press, New York.
- MacFall JR, Charles HC, Black RD, et al. (1996) Human lung air spaces: potential for MR imaging with hyperpolarized He-3. Radiology 200: 553–558.
- Marks MP, de Crespigny A, Lentz D, Enzmann DR, Albers GW, Moseley ME (1996) Acute and chronic stroke: navigated spin-echo diffusion-weighted MR imaging. Radiology 199: 403–408.
- Mezrich R (1995) A perspective on k-space. Radiology 195: 297–315; Radiology 199: 874–785.
- Mills I (ed.) (1989) Quantities, Units, and Symbols in Physical Chemistry. International Union of Pure and Applied Chemistry, Physical Chemistry Division. Blackwell, Oxford, UK.
- Mugler JP, III, Brookeman JR (1988) The optimum data sampling period for maximum signal-to-noise ratio in MR imaging. Reviews in Magnetic Resonance Imaging 3: 1–51.
- Mugler JP, III, Driehuys B, Brookeman JR, et al. (1997) MR imaging and spectroscopy using hyperpolarized 129Xe gas: preliminary human results. Magnetic Resonance in Medicine 37: 809–815.
- Mukherji SK (ed.) (1998) Clinical Applications of MR Spectroscopy. Wiley-Liss, New York.
- Nazarian S, Roguin A, Zviman MM, et al. (2006) Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla. Circulation 114: 1277–1284.
- Neil JJ (1997) Measurement of water motion (apparent diffusion) in biological systems. Concepts in Magnetic Resonance 9: 385–401.
- Nitz WR (1999) MR imaging: acronyms and clinical applications. European Radiology 9: 979–997.
- Oosterwijk H (2000) DICOM Basics. Cap Gemini Ernst & Young.
- Parker DL, Guilberg G (1990) Signal-to-noise efficiency in magnetic resonance imaging. Medical Physics 17: 250–257.
- Pinker K, Stadlbauer A, Bogner W, Gruber S, Helbich TH (2012) Molecular imaging of cancer: MR spectroscopy and beyond. European Journal of Radiology March, 81(3): 566–577. doi: 10.1016/j.ejrad.2010.04.028. Epub 2010 Jun 4.
- Pipe JG, Chenevert TL (1991 A progressive gradient moment nulling design technique. Magnetic Resonance in Medicine 19: 175–179.
- Port M, Idee J-M, Medina C, Robic C, Sabatou M, Corot C. (2008) Efficiency, thermodynamic and kinetic stability of marketed gadolinium chelates and their possible clinical consequences: a critical review. Biometals 21: 469–490.
- Prüssmann, KP, Weiger M, Scheidegger MB, Bösiger P (1999) SENSE: sensitivity encoding for fast MRI. Magnetic Resonance in Medicine 42: 952–962.
- Runge VM, Nitz WR, Schmeets SH, Schoenberg SO (2007) Clinical 3T Magnetic Resonance. Thieme Medical Publishers, New York.
- Salibi N, Brown MA (1998.) Clinical MR Spectroscopy: First Principles. Wiley-Liss, New York.
- Sandstede JJW, Lipke C, Beer M, et al. (2000) Analysis of first-pass and delayed contrast-enhancement patterns of dysfunctional myocardium on MR imaging: use in the prediction of myocardial viability. AJR 174: 1737–1740.
- Semelka RC (2005) Abdominal-Pelvic MRI, 2nd edition. Wiley-Liss, New York.
- Shellock FG (2009) The Reference Manual for Magnetic Resonance Safety. Implants and Devices 2009. Biomedical Research Publishing Company, Los Angeles, CA.
- Shellock FG, Crues JV (2004) MR procedures: biologic effects, safety, and patient care. Radiology 232: 635–652.
- Shellock FG, Spinazzi A (2008) MRI safety pdate 2008: Part 1, MRI contrast agents and nephrogenic systemic fibrosis. Am J Roentgenol 191: 1129–1139; Part 2, Screening patients for MRI. Am J Roentgenol 191: 1140–1149.
- Slichter CP (1996) Principles of Magnetic Resonance, 3rd edition. Springer-Verlag, Heidelberg.
- Sodickson DK, Manning WJ (1997) Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency arrays. Magnetic Resonance in Medicine 38: 591–603.
- Sodickson DK., McKenzie CA (2001) A generalized approach to parallel magnetic resonance imaging. Medical Physics 28: 1629–1643.
- Sommer T, Naehle CP, Yang A, et al. (2006) Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations. Circulation 114: 1285–1292.
- Stejskal EO, Tanner JE (1965) Spin diffusion measurements: spin echoes in the Presence of a Time-Dependent Field Gradient. Journal of Chemical Physics 42, 288-292.
- Tannús A, Garwood M (1997) Adiabatic pulses. NMR in Biomedicine 10: 423–434.
- Thomsen HS (2014) ESUR Guidelines on Contrast Media, Version 9.0. European Society of Urogenital Radiology.
- US Food and Drug Administration. (2006) Information on Gadolinium-Containing Contrast Agents. Center for Drug Evaluation and Research. http://www.fda.gov/cder/drug/infopage/gcca/default.htm.
- US Government (2008) Code of Federal Regulations, Title 21, Volume 8, Subpart B, Section 892.1000, revised 2008: Magnetic resonance diagnostic device (21CFR892.1000).
- Vaughan JT, Snyder CJ, DelaBarre LJ, et al. (2009) Whole-body imaging at 7T: preliminary results. Magnetic Resonance in Medicine 61: 244–248.
- Wilke NM, Jerosh-Herold M, Zenovich A, and Arthur Stillman A (1999) Magnetic resonance first-pass myocardial perfusion imaging: clinical validation and future applications. Journal of Magnetic Resonance Imaging 10: 676–685.
- Wolff SD, Balaban RS (1994) Magnetization transfer imaging: practical aspects and clinical applications. Radiology 192: 593–599.
- Wong EC, Buxton RB, Frank LR (1998) A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magnetic Resonance in Medicine 40: 348–355.
- Young IR (2000) Notes on current safety issues in MRI. NMR in Biomedicine 13: 109–115.